¡ß Intrinsic safety and increased safety type thermocouple and resistance temperature detector ¡ß
¡Ü Model : R950 : R951-R952-R953-R954-R955-R956-R957-R958-R95A-R95B-R95C-R95D (ETR10 series)
¡Ü Service intended :
Measuring the temperature in the area where combustible gas, particles and flammable liquid exist can be a very dangerous task. The electrical energy of measuring instrument is lower than electric motor, however, the malfunction of the instrument or the accident can cause to start the explosion. Therefore, ETR10 series is explosion proof type product which is designed to be used in a critical danger zone (Ex e=Zone 1, Ex ia=Zone 0) by acquiring IECEx and ATEX certification.
¡Ü Examination certificate :
- ATEX II 1/2G Ex ia IIC T6...T1 Ga/Gb
- IECEx Ex ia IIC T6...T1 Ga/Gb
Ui = 30 V, Li = 100 mA, Pi = see the instruction manual
Ci = 0.1 nF, Li = 0.01 mH
- ATEX 2G Ex e IIC T6...T1 Gb
- IECEx Ex e IIC T6...T1 Gb
¡Ü Element :
- Thermocouple : K, E
- RTD : Pt 100§Ù at 0¡É
¡Ü Standard nipple material : 304SS (Head type only)
¡Ü Standard nipple length : 100 or 150 mm (Head type only)
¡Ü Enclosure material :Die cast aluminium (ALDC) or 316SS (Head type only)
¡Ü Standard measuring material : 316SS
¡Ü Electrical rating : 10 mA 4 VDC resistance load
¡Ü Standard process connection : ¨ö" NPT
¡Ü Ambient temperature :
- -20 ~ +60¡É (Ex ia)
- -40 ~ +65¡É (Ex e)
|