¡ß Electromagnetic flowmeters combined type ¡ß
¡Ü Model : F950
¡Ü Description :
The Electromagnetic Flowmeter can be used to accurately measure the flowrate of liquids, paper pulp, slurry and mineral slurry which has an electrical conductivity greater than 10 µs/cm.
F950 is a flow measurement system in a compact design which integrates the primary and signal converter.
¡Ü Applications :
- Facilities in water supply, sewerage, agricultural water, industrial water and waste water
- Petrochemical, alkali salt, chemicals and coolant process.
- Circulating water like cement sludge, coal sludge
- Spoke water, waste water, coolant in pulp, paper mill
- Coolant, seawater circulating, in ship building factories
¡Ü Type : Combined type
¡Ü Size : 15 ~ 1,000A (¨ü"~40")
¡Ü Process connection : Flange type [ANSI, ASME, DIN, JIS, KS, ETC.]
¡Ü Measuring range : 0.2 - 10 m/s
¡Ü Accuracy :
¡¤¡Ã 10 µs/cm
¡¤Option : ¡Ã 5 µs/cm
¡Ü Lining :
- Standard : Hard rubber (0 ~ 60 ¡ÆC)
- Option : Teflon (-10 ~ 160 ¡ÆC) Max. 600A
¡Ü Ambient temperature : -10 ~ 60 ¡ÆC
¡Ü Conductivity :
- Standard : ¡Ã 10 µs/cm
- Option : ¡Ã 5 µs/cm
¡Ü Power supply :
- Standard : AC 85 ~ 250 V, 50 ~ 60 Hz
- Option : DC 24 V [2-Wire Loop Power]
¡Ü Power consumption : Max. 15 VA
¡Ü Display :
- LCD Display with back light
- Flowrate : 5-Digit Display
- Total : 9-Digit Display
¡Ü Output :
- Analog : DC 4 ~ 20 mA (Isolated) - Active
- Pulse : Open collector pulse
- Communication : RS485
¡Ü Protection class :
- Standard : Weather Proof - IP66
- Option : Ex-Proof (Ex d IIC T5_IP66)
¡Ü Special feature :
- Self check
- Empty pipe
- Enable to reverse flow direction
- Data logging
- Error message
|