¡Ú ÀüÀÚ Àú¿ï
¡Ú ¿Âµµ°è
¡Ú ¾Ð·Â°è
¡Ú À¯·®°è¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡
¼öÁú | ¼öºÐ | ´çµµ | ¿°µµ°è
°¡½º | ȯ°æ | dz¼Ó°è
Á¶µµ | »öÂ÷ | ¼ÒÀ½ | Áøµ¿°è
±æÀÌ | ÃøÁ¤°ø±¸
ȸÀü | °æµµ°è | °Ë»ç°æ | È®´ë°æ
½ÇÇè±â±¸ | ÀÌÈ­Çбâ±â¡¡¡¡¡¡¡¡¡¡¡¡¡¡
¡Ú ±â·Ï | Áö½Ã | º¯È¯ | Á¶Àý°è¡¡¡¡¡¡¡¡
Àü±â °èÃø±â¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡
¡Ú Àü¹® ºê·£µå¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡
¡Ú Ä«½º CAS ÀüÀÚÀú¿ï Àü¹® °ø½Ä ´ë¸®Á¡ A/S ¼­ºñ½º ¼¾ÅÍ
¡Ú ¿ÍÀÌÁî»êÀü WISE °ø½Ä ´ë¸®Á¡
¡Ú Äڴнº KONICS ¿ÀÅä´Ð½º AUTONICS °ø½Ä´ë¸®Á¡
¡Ú Ų½º°è±â KINS °ø½Ä ´ë¸®Á¡
¡Ú ´ºÀνº NEWINS °ø½Ä´ë¸®Á¡¡¡¡¡¡¡
¡Ú ȸ»ç ÁÖ¼Ò | Á¦Á¶»ç¡¡¡¡¡¡¡¡¡¡¡¡
°æ±âµµ ½ÃÈï½Ã °ø´Ü1´ë·Î244 (Á¤¿Õµ¿, ½ÃÈ­À¯Åë»ó°¡ 12µ¿ 123È£)
°æ±âµµ ¾È»ê½Ã ´Ü¿ø±¸ »ê´Ü·Î326 (¿ø°îµ¿, À¯Åë»ó°¡ 17µ¿ 120È£)
°æ±â È­¼º ÆÈź¸é ¼­ÇØ·Î1121¹ø±æ7 ¹ß¾ÈÇö´ë°ø±¸Å¸¿î 502-104
¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡Ú Àú¿ï¡¤°è·®°èÃø±â Àü¹®
¡Ú Á¦¾î°èÃø±â Àü¹®
¡Ú ½ÇÇè½Ç ÀÌÈ­Çбâ±â Àü¹®
¡Ú ÃøÁ¤°ø±¸ Àü¹®
¡Ú ±¹°¡°øÀαâ°ü °Ë±³Á¤ ´ëÇà¡¡¡¡¡¡¡¡
¡Ú Çѱ¹À¯·®°è°ø¾÷ KOMETER
¡Ú µå¿ÍÀ̾î DWYER¡¡¡¡¡¡¡¡¡¡¡¡¡¡
¹Ì¾²µµ¿ä MITUTOYO¡¡¡¡¡¡¡¡¡¡¡¡¡¡
±Û·Î¹ú·¦ GLOBAL LAB
¹Ì¼º°úÇÐ MISUNG SCIENTIFIC
 
Á¦Ç°¼Ò°³ / ¡Ú ¿Âµµ°è
¡Ú ¿Âµµ°è¡· Ä«Å×°í¸® ºÐ·ù
 
Á¦ Ç° ¸í   R920 : R921, R922 (RS series)
¸ðµ¨¸í   R920 : R921, R922 (RS series)
Á¦Á¶È¸»ç   WISE
¹®ÀǸ¦ ¿øÇϽô °í°´²²¼­´Â °í°´¼¾ÅÍ [½ÃÈ­] 031-430-6641 [¾È»ê] 031-508-4900 [È­¼º] 031-352-4509 À¸·Î ÀüÈ­¸¦ Áֽøé Ä£ÀýÇÏ°í ½Å¼ÓÇÏ°Ô »ó´ãÇØ µå¸³´Ï´Ù.
          
 
¡ß Explosion proof type Sheathed thermocouple and resistance temperature detector with spring load ¡ß

¡Ü Model : R920 : R921, R922 (RS series)

¡Ü Service intended :
Generally, sheathed type temperature sensors are used with thermowell. To maximize the heat-transfer between sheath junction and thermowell, the sheath must be inserted as close as possible to the bottom of the well. However, it is not always possible to determine the actual distance between the end tip of the sheath and the bottom of the thermowell. Furthemore, heat expansion can damage the sheath which is located inside the thermowell. To prevent this uncertainty and the damage to the sheath, RS series employ the spring load type sheath. This spring load absorbs the impact to the sheath, and protects the sheath from the vibration. Moreover, it is designed to be used in an explosive area.

¡Ü Examination certificat : Ex d IIC T6 IP65

¡Ü Element :
- Thermocouple : K, E, J, T, N
- R.T.D. : Pt 100§Ù at 0¡É

¡Ü Tolerances on temperature reading :
- Thermocouple :
£ª Class 1, Class 2 (DIN/IEC584-2, BS/EN60584-2, JIS C1602)
£ª Special, Standard (ASTM E230 E988 ISA-MC96.1)
- R.T.D :
£ª Class A : ¡¾ (0.15 + 0.002 l t l)
£ª Class B : ¡¾ (0.3 + 0.005 l t l)

¡Ü Head material :
- ALDC (Standard)
- 316SS

¡Ü Sheath outer diameters :
- Thermocouple : 1.0, 1.6, 2.3, 3.2, 4.8, 6.4, 8.0, 9.5 and 12.7 mm
* Double elements is not available for 1.0 and 1.6 mm

¡Ü sheath outer diameters :
- R.T.D. : 3.2, 4.8, 6.4 and 8.0 mm







Ä«´Ù·Î±×
¿Âµµ¼¾¼­ »ç¿ëÀÚ ¸Þ´º¾ó - ±¹¹®
»ç¿ëÀÚ ¸Þ´º¾ó - ¿µ¹®
IP ½ÃÇè ¼ºÀû¼­
KCS ¹æÆø ÀÎÁõ¼­
±× ¿Ü Á¦Ç° ÀÎÁõ¼­